International QEEG Certification Board Guideline Minimum Technical Requirements for Performing Clinical Quantitative Electroencephalography

STS Instructor Authored by David Cantor, Robert Turner and Thomas Collura

Share

Suggested message

Check out this Knowledge Base article from StressTherapy Solutions: International QEEG Certification Board Guideline Minimum Technical Requirements for Performing Clinical Quantitative Electroencephalography.

Facebook LinkedIn Email

Facebook doesn't let websites fill in your post. Use Copy message, then paste it in.

Study at a glance

Area
QEEG, Methods & Mechanisms
Authors
Collura T, Cantor D, Chartier D, Crago R, Hartzoge A, Hurd M, Kerson C, Lubar J, Nash J, Prichep LS, et al.
Journal
Clinical EEG and Neuroscience
Year
2025

Key findings

  • Data acquisition should follow ACNS standards for multichannel EEG
  • Expanded guidance on artifact management and visual review for paroxysmal events
  • Requirements set for EEG selection, quality reporting and spectral/statistical/topographic analysis
  • Reviews well-validated QEEG features, LORETA and classifier methods, with cautions on their use

A professional guideline, backed by the International QEEG Certification Board, setting out the minimum technical standards for doing clinical QEEG. It builds on American Clinical Neurophysiology Society recording standards, with added detail on handling artifact and visually checking the raw EEG for paroxysmal events, and adds requirements for choosing EEG segments, reporting data quality and running spectral, statistical and topographic analyses. It also reviews the most established QEEG measures and tools such as LORETA and classifiers, with cautions, stressing that results are only as good as the recording and processing behind them.