Research › QEEG, Methods & Mechanisms
Real-time filtering for the estimation of steady-state visual evoked brain potentials
STS Instructor Authored by Thomas Collura
Share
Study at a glance
- Area
- QEEG, Methods & Mechanisms
- Authors
- Collura TF
- Journal
- IEEE Transactions on Biomedical Engineering
- Year
- 1990
- Protocol
- comb filtering of steady-state visual evoked potentials
Key findings
- Steady-state visual evoked potentials can be estimated continuously rather than by averaging
- A comb filter isolates the response's main harmonics
- The method tracks moment-to-moment changes in the response
- Demonstrated on human subjects
A brief engineering paper showing that the brain's response to a repeating visual stimulus (between 2 and 20 flashes per second) can be measured in real time with a simple filter, without lengthy averaging. A comb filter lets through the key harmonic frequencies of the response, giving an estimate of the evoked activity and following how it changes over time. Tests on human volunteers supported the method.